JVL16-63 Residual Current Circuit Breaker

Construction and Feature

Elegant appearance; cover and handle in arc shape make comfortable operation. Contact position indicating window

Transparent cover designed to carry label.

In case of overload to protected circuit,RCCB handle trips and stays at central position, which enables a quick solution to the faulty line. The handle cannot stay in such position when operated manually.

Provides protection against earth fault/leakage current and function of isolation. High short-circuit current withstand capacity

Applicable to terminal and pin/fork type busbar connection Equipped with finger protected connection terminals

Fire resistant plastic parts endures abnormal heating and strong impact

Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity.

Independent of power supply and line voltage, and free from external interference,voltage fluctuation.

分类:

描述

Construction and Feature

Elegant appearance; cover and handle in arc shape make comfortable operation. Contact position indicating window

Transparent cover designed to carry label.

In case of overload to protected circuit,RCCB handle trips and stays at central position, which enables a quick solution to the faulty line. The handle cannot stay in such position when operated manually.

Provides protection against earth fault/leakage current and function of isolation. High short-circuit current withstand capacity

Applicable to terminal and pin/fork type busbar connection Equipped with finger protected connection terminals

Fire resistant plastic parts endures abnormal heating and strong impact

Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity.

Independent of power supply and line voltage, and free from external interference,voltage fluctuation.

 

Technical Data

Mode: electro-magnetic type

Residual current characteristics: A,AC,G,S

Pole No.: 2,4

Rated making and breaking capacity:500A(ln=25A,40A) or 630A(In=63A)

Rated current(A): 25,40,63

Rated voltage:AC 230(240)/400(415)

Rated frequency: 50/60Hz

Rated residual operating current I△n(A):0.03,0.1,0.3,0.5

Rated residual non operating current I△no:0.5I△n

Rated conditional short-circuit current Inc:10kA

Rated conditional residual short-circuit Current I△c:10kA

Residual tripping current range:0.5I△n~l△n

Terminal Connection Height:19mm

Electro-mechanical endurance:4000cycles

Connection capacity: Rigid conductor 25mm²

Connection terminal:Screw terminal

Pillar terminal with clamp Fastening torque: 2.0Nm

Installation:

On symmetrical DIN rail 35mm

Panel mounting

Protection class:IP20